Division KELLER
Jobs + Career
News
Events
Media center
Contact
EN
language choice
Search
Sign in
shopping cart
Please choose your language:
Search results
Sign in
User name/E-mail
Password
Sign in
Division KELLER
Menu
Temperature measurement
Pyrometer
Product finder
Pyrometer CellaTemp PK 18
Jobs + Career
News
Events
Media center
Contact
EN
About us
About us
Division KELLER
Purchase
Corporate policy
Locations
Company history
Application solutions
Pyrometer
Pyrometer
PX series
PA series
PK series
PR series
PZ series
PT series
Mikro series
Measuring systems
Accessories
Product finder
KITS Service App
Reports
Reports
Basics
Basics of infrared temperature measurement
Optical influences
Definition and influence of emissivity
Metrological errors
Two-colour pyrometers
Panorama pyrometers
IO-Link
Building materials
Foundry
Steel
Induction
Glass
Glow strips
Furnace
Combustion plant
Aluminium
Wood gluing
Videos
Tools
Tools
Measuring field calculator
Emissivity calculator
Mounting combinations
Product Finder
Troubleshooting
Software
Software
Software CellaView
IO-Link Communication Tool
Service
Contact
Contact
Contact persons
International
Request
General applications
Liquid metals
Incinerators
Artificial diamonds
PLD processes
SiC production
IO-Link
Glossary
Pyrometer CellaTemp PK 18
Article description
Das CellaTemp® PK 18 has a special resistant lens. This allows its usage even in extreme environmental conditions, such as in asphalt and concrete mixing plants, without damaging the lens by aggressive vapours and dusts.
Special features:
Measuring range 0 to 500 °C
special resistant lens for use in extreme ambient conditions
switching output universally configurable
high optical resolution due to precision lenses
IO-Link interface
all parameters can be set via pushbutton on the sensor or via interface from the plant control system
test function can be triggered by pushbutton or control signal
very simple mounting via M30 central thread
large and bright LED display
Pyrometer CellaTemp PK 18
Properties
Version
Measuring range
0 - 500 °C
0 - 500 °C
Focus distance
0,3 m
0,3 m
Your selection will affect other settings
Version
AF 1
You can request this article from us
Quantity:
Request article
More information about IO-Link:
Version
CellaTemp PK 18 AF 1
Measuring range
0 - 500 °C
Target size
11 mm
Focus distance
0,3 m
Shape of the measuring field
round
Measuring principle
one-colour
Technical Data
Downloads
Measuring field calculator
Accessories
Emissivity calculator
Application request
IO-Link IODD
IO-Link Manufacturer explanation
Pyrometer CellaTemp PK 18
Technical Data
Measurement parameters
Measuring range
0 - 500 °C
Sensor
Thermopile
Spectral range
8 - 14 µm
Response time t90
≤ 60 ms
Measurement uncertainty
0.75 % of temp. reading [°C] plus 2.0 K
Repeatability
1 K
Temperature coefficient
0.1 K/K (T < 250 °C)
0.04 %/K (T > 250 °C)
Resolution current output
0.2 K + 0.03 % of selected range
Resolution interface
0.1 K
Resolution display
0.1 K < 200 °C
1 K ≥ 200 °C
Electrical parameters
Analog output
0(4) - 20 mA linear, switchable, scalable
Resistance
≤ 500 Ω
Switching output
Open Collector 24 V DC, ≤ 150 mA
Test input
10 - 34 V DC (acc. to IEC 61131-2)
Interface
IO-Link
Power supply
24 V DC +10 % / -20 %
Current consumption
≤ 50 mA at 24 V DC
Features
Display
4-digit LED display red, digit-height 8 mm
Status display
2 x LED
Control elements
3 buttons
General parameters
Connection
M12 thread 5-pin connection (A-coding)
Ambient temperature
0 - 65 °C
Storage temperature
-20 - +80 °C
Permissible humidity
95 % r.H. max. (non-condensing)
Dimension
Ø 30 x 185 mm (without plug)
Housing
Stainless steel V2A (1.4305)
Protection class
IP 65 acc. to DIN 40050
Weight
approx. 0.4 kg
Adjustable parameters
Parameters
Analog output 0/4 - 20 mA
Scaling of the analogue output
Quick emissivity setting via temperature display
Damping time constant
Hold time of the maximum value memory
Operation mode and switching points of the switching contact
Reset to factory setting
Key lock
Temperature display
Temperature unit °C/°F
Simulation of temperature
Test function
Functions
Overtemperature signal
Signal display at an internal temperature > 75 °C
Test function
via button or test input
Service function
Simulation of a measured value
Diagnostic function
Indicates in case of reverse polarity, overload and wrong supply voltage
Reverse polarity protection
for power supply, analogue output and switching output
Scope of delivery
Scope of delivery
Infrared thermometer CellaTemp PK
Manual (short)
2 fixing nuts
Pyrometer CellaTemp PK 18
Emissivity calculator
Calculation of the emissivity to be set
The correct emissivity to be set on the pyrometer is calculated from the measured value displayed on the pyrometer, the true object temperature, the emissivity preset on the pyrometer and the ambient temperature (necessary for some types).
Calculation of the measured value
From the true object temperature, the emissivity of the measurement object, the emissivity set on the pyrometer and the ambient temperature (required for types), the measured value calculated by the pyrometer is displayed.
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Emissivity ratio to be set
-
+
Ambient temperature
-
+
Object temperature
-
+
Measured value of the pyrometer
Pyrometer
Quotient
Two-colour mode
One-colour 1
One-colour 2
Preset emissivity
-
+
Measured value of the pyrometer
-
+
Ambient temperature
-
+
Object temperature
-
+
Emissivity ratio to be set
Pyrometer CellaTemp PK 18
Downloads
Brochure CellaTemp PK PKF PKL
Brochure Flyer IO-Link
Manual CellaTemp PKx IO-Link
Quick guide CellaTemp PKxx IO-Link
Declaration of conformity Declaration from Conformity PKxy
UKCA Declaration from Conformity PKxy
EAC Deklaration PK-PA-PT
X
Pyrometer CellaTemp PK 18
Accessories
Software
Electrical accessories
Mechanical accessories
Mountings
Air purge PS 01/A AF 1
Add to shopping cart
Air purge PS 01/A AF 2
Add to shopping cart
Bayonet coupling PS 11/N AF 4
Add to shopping cart
Bayonet coupling PS 11/N AF 5
Add to shopping cart
Cable VK 02/L AF 1
Add to shopping cart
Cable VK 02/L AF 2
Add to shopping cart
Cable VK 02/L AF 3
Add to shopping cart
Cable VK 02/O
Add to shopping cart
Cable VK 02/R AF 1
Add to shopping cart
Cable VK 03/A AF 1
Add to shopping cart
Cable VK 03/A AF 2
Add to shopping cart
Clamp ZA 01/E
Add to shopping cart
Clamp ZA 01/T
Add to shopping cart
Clamping collar PS 11/K AF 2
Add to shopping cart
Clamping collar PS 11/K-35 AF 2
Add to shopping cart
Clamping shaft ZA 01/D
Add to shopping cart
Cooling jacket PK 01/B AF 1
Add to shopping cart
Cooling jacket PK 01/C AF 1
Add to shopping cart
Cooling jacket PK 01/C AF 2
Add to shopping cart
Deflection mirror PS 01/R
Add to shopping cart
Deflection mirror PS 11/W AF 1
Add to shopping cart
Digital display DA 230A
Add to shopping cart
Dust stop ZA 01/C
Add to shopping cart
Flange PS 01/N
Add to shopping cart
Flange ZA 01/I
Add to shopping cart
Intermediate tube ZA 01/B
Add to shopping cart
Intermediate tube ZA 01/M
Add to shopping cart
IO-Link software SW 50 AF 1
Junction box VK 30.02
Add to shopping cart
Mounting bracket PS 11/P AF 1
Add to shopping cart
Mounting bracket set PS 11/U
Add to shopping cart
Mounting flange Flansch DN 50 - R1.1/4"
Add to shopping cart
Mounting PK 01-006
Upon request
Mounting PK 01-007
Upon request
Mounting PK 01-011
Upon request
Mounting PK 01-014
Upon request
Mounting PK 01-022
Upon request
Mounting PK 01-023
Upon request
Mounting PK 01-024
Upon request
Mounting PK 01-027
Upon request
Mounting PK 01-028
Upon request
Mounting PK 01-029
Upon request
Mounting PK 11-001
Upon request
Mounting PK 11-006
Upon request
Mounting PK 11-008
Upon request
Plate ZA 01/S
Add to shopping cart
Plate ZA 01/W
Add to shopping cart
Supplementary tube ZA 01/Q AF 2
Add to shopping cart
Supplementary tube ZA 01/Q AF 3
Add to shopping cart
Supplementary tube ZA 01/Q-35 AF 1
Add to shopping cart
Thermal insulating tube PS 01/K
Add to shopping cart
Tube cap ZA 01/A
Add to shopping cart
ZnS window PS 11/D AF 2
Add to shopping cart
Pyrometer CellaTemp PK 18
IO-Link IODD
Type
Datei
Dateigröße
IODD PK18AF1_20221222.zip
378 KB
Download
IODD PK18AF2_20190123.zip
421 KB
Download
Pyrometer CellaTemp PK 18
IO-Link Manufacturer explanation
Type
Datei
Dateigröße
MC PK 18 AF 1_202302_en.pdf
100 KB
Download
Pyrometer CellaTemp PK 18
Measuring field calculator
Pyrometer
PK 18 AF 1
(0,3 m)
PK 18 AF 1
(0,3 m)
Graphic length
mm
Calculate
Print
Measuring distance (mm)
0
24
48
72
96
120
144
168
192
216
240
264
288
11.00 mm
Measuring distance
Measuring field diameter
0.00 mm
16.50 mm
12.00 mm
16.28 mm
24.00 mm
16.06 mm
36.00 mm
15.84 mm
48.00 mm
15.62 mm
60.00 mm
15.40 mm
72.00 mm
15.18 mm
84.00 mm
14.96 mm
96.00 mm
14.74 mm
108.00 mm
14.52 mm
120.00 mm
14.30 mm
132.00 mm
14.08 mm
144.00 mm
13.86 mm
156.00 mm
13.64 mm
168.00 mm
13.42 mm
180.00 mm
13.20 mm
192.00 mm
12.98 mm
204.00 mm
12.76 mm
216.00 mm
12.54 mm
228.00 mm
12.32 mm
240.00 mm
12.10 mm
252.00 mm
11.88 mm
264.00 mm
11.66 mm
276.00 mm
11.44 mm
288.00 mm
11.22 mm
300.00 mm
11.00 mm
Request
Shipping costs for
Deutschland
Andorra
United Arab Emirates
Afghanistan
Antigua and Barbuda
Anguilla
Albania
Armenia
Netherlands Antilles
Angola
Antarctica
Argentina
American Samoa
Austria
Australia
Aruba
Azerbaijan
Bosnia and Herzegovina
Barbados
Bangladesh
Belgium
Burkina Faso
Bulgaria
Bahrain
Burundi
Benin
Bermuda
Brunei Darussalam
Bolivia
Brazil
Bahamas
Bhutan
Bouvet Island
Botswana
Belarus
Belize
Canada
Cocos (Keeling) Islands
Congo, the Democratic Republic of the
Central African Republic
Congo
Switzerland
Cote D'Ivoire
Cook Islands
Chile
Cameroon
China
Colombia
Costa Rica
Serbia and Montenegro
Cuba
Cape Verde
Christmas Island
Cyprus
Czech Republic
Germany
Djibouti
Denmark
Dominica
Dominican Republic
Algeria
Ecuador
Estonia
Egypt
Western Sahara
Eritrea
Spain
Ethiopia
Finland
Fiji
Falkland Islands (Malvinas)
Micronesia, Federated States of
Faroe Islands
France
Gabon
United Kingdom
Grenada
Georgia
French Guiana
Ghana
Gibraltar
Greenland
Gambia
Guinea
Guadeloupe
Equatorial Guinea
Greece
South Georgia and the South Sandwich Islands
Guatemala
Guam
Guinea-Bissau
Guyana
Hong Kong
Heard Island and Mcdonald Islands
Honduras
Croatia
Haiti
Hungary
Indonesia
Ireland
Israel
India
British Indian Ocean Territory
Iraq
Iran, Islamic Republic of
Iceland
Italy
Jamaica
Jordan
Japan
Kenya
Kyrgyzstan
Cambodia
Kiribati
Comoros
Saint Kitts and Nevis
Korea, Democratic People's Republic of
Korea, Republic of
Kuwait
Cayman Islands
Kazakhstan
Lao People's Democratic Republic
Lebanon
Saint Lucia
Liechtenstein
Sri Lanka
Liberia
Lesotho
Lithuania
Luxembourg
Latvia
Libyan Arab Jamahiriya
Morocco
Monaco
Moldova, Republic of
Madagascar
Marshall Islands
Macedonia, the Former Yugoslav Republic of
Mali
Myanmar
Mongolia
Macao
Northern Mariana Islands
Martinique
Mauritania
Montserrat
Malta
Mauritius
Maldives
Malawi
Mexico
Malaysia
Mozambique
Namibia
New Caledonia
Niger
Norfolk Island
Nigeria
Nicaragua
Netherlands
Norway
Nepal
Nauru
Niue
New Zealand
Oman
Panama
Peru
French Polynesia
Papua New Guinea
Philippines
Pakistan
Poland
Saint Pierre and Miquelon
Pitcairn
Puerto Rico
Palestinian Territory, Occupied
Portugal
Palau
Paraguay
Qatar
Reunion
Romania
Russian Federation
Rwanda
Saudi Arabia
Solomon Islands
Seychelles
Sudan
Sweden
Singapore
Saint Helena
Slovenia
Svalbard and Jan Mayen
Slovakia
Sierra Leone
San Marino
Senegal
Somalia
Suriname
Sao Tome and Principe
El Salvador
Syrian Arab Republic
Swaziland
Turks and Caicos Islands
Chad
French Southern Territories
Togo
Thailand
Tajikistan
Tokelau
Timor-Leste
Turkmenistan
Tunisia
Tonga
Turkey
Trinidad and Tobago
Tuvalu
Taiwan, Province of China
Tanzania, United Republic of
Ukraine
Uganda
United States Minor Outlying Islands
United States
Uruguay
Uzbekistan
Holy See (Vatican City State)
Saint Vincent and the Grenadines
Venezuela
Virgin Islands, British
Virgin Islands, U.s.
Viet Nam
Vanuatu
Wallis and Futuna
Samoa
Yemen
Mayotte
South Africa
Zambia
Zimbabwe
Back
To the checkout
Reference number:
INDICE 6
Login
Anmelden
Abbrechen
Anmelden
Abbrechen
© 2001-2024 –
Internetagentur
– Wrocklage Werbewerkstatt