Assembly PA 43

Error category
Switching output
Problem
Connected load does not switch on
Possible cause
Connected load is too high - out LED flashes
Solution
Check connected load, if necessary control via load relay
Possible cause
Switching thresholds and/or switching times incorrectly parameterized
Solution
Check whether the Out LED on the pyrometer switches Check parameters of the switching output
Possible cause
Defective connector plug
Solution
Check the connector plug for damage
Check the connector plug for damage
Possible cause
Switching output incorrectly connected
Solution
Check correct connection of the pyrometer
Check correct connection of the pyrometer